TEMPERATURE

Operating Measurement:...............Indoor: 32 degrees to 122 degrees F
                                             (0 degrees to 50 degrees C)
                                   Outdoor: -40 degrees to 140 degrees F
                                           (-40 degrees to 60 degrees C)

Indoor Measurement Accuracy:

  Range: 32 degrees to 105 degrees F......................+/-2 degrees F
         (0 degrees to 40 degrees C).....................(+/-1 degrees C

  Range: 105 degrees to 123 degrees F.....................+/-4 degrees F
         (40 degrees to 50 degrees C)...................(+/-2 degrees C)


Outdoor Measurement Accuracy:...........................

  Range: - 40 degrees to <32 degrees F....................+/-4 degrees F
         (-40 degrees to <0C)............................(+/-2 degrees C

  Range: > 32 degrees to 105 degrees F....................+/-2 degrees F
         (> 0 degrees to 40 degrees C)..................(+/-1 degrees C)

  Range: > 105 degrees to 122 degrees F...................+/-4 degrees F
         (> 40 degrees to 50 degrees C).................(+/-2 degrees C)

Range: > 122 degrees to 140 degrees F.....................+/-6 degrees F
         (>50 degrees to 60 degrees C)..................(+/-3 degrees C)

Resolution (Indoor and Outdoor):...........0.2 degrees F (0.1 degrees C)

Sampling Cycle Frequency (Indoor and Outdoor):................10 seconds


RELATIVE HUMIDITY

Operating Measurement:.........................................10 to 97%

Accuracy:

   Indoor Range: 25-90%....................................+/-7% Maximum

   Outdoor Range: 25-90%....................................+/-8 Maximum

Resolution (Indoor and Outdoor):......................................1%

Sampling Cycle Frequency (Indoor and Outdoor):................10 seconds


DEW POINT TEMPERATURE

Operating Measurement:...............Indoor: 32 degrees to 117 degrees F
                                             (0 degrees to 47 degrees C)
                                    Outdoor: 32 degrees or 133 degrees F
                                             (0 degrees to 56 degrees C)


Indoor Measurement Accuracy:

   Range: 25-40% RH:.....................................+/-14 degrees F
                                                        (+/-7 degrees C)

   Range: 40-90% RH:.....................................+/-10 degrees F
                                                        (+/-5 degrees C)

   Range:....................................32 degrees to 105 degrees F
                                             (0 degrees to 40 degrees C)


Outdoor Measurement Accuracy:

   Range: 25-40% RH:.....................................+/-16 degrees F
                                                        (+/-8 degrees C)

   Range: 40-90% RH:.....................................+/-12 degrees F
                                                        (+/-6 degrees C)
   Range:....................................32 degrees to 105 degrees F
                                             (0 degrees to 40 degrees C)

Resolution (Indoor and Outdoor):...............2 degrees F (1 degrees C)

Sampling Cycle Frequency (Indoor and Outdoor):................10 seconds


BAROMETRIC PRESSURE/TREND

Operating Measurement:..............23.48 to 31.01 inHg (795 to 1050 mb)

Accuracy: Range: 32 degrees to 123 degrees F.......+/-.21 inHg (+/-7 mb)
(0 degrees to 50 degrees C):

Resolution:...............................................03 inHg (1 mb)

Pressure Sampling Cycle Frequency:............................15 minutes

Trend Sampling Cycle Frequency:...................................1 hour


WIND SPEED

Operating Measurement:......................0 to 125.3 mph (0 to 56 m/s)

Measurement Accuracy:

   Range 4 degrees to 140 degrees F.............................+/-1 m/s
   (-20 degrees to 60 degrees C)
   Range: 2 to >20 m/s

   Range: 4 degrees to 140 degrees F...............................+/-5%
   (-20 degrees to 60 degrees C)
   Range: 20 to 56 m/s

Resolution:............................................0.2 m/s (0.4 mph)

Sampling Cycle Frequency:......................Gust Wind Mode: 5 seconds
                                             Average Wind Mode: 1 minute


WIND DIRECTION

Operating Measurement:........................0 degrees to 359 (Degrees)
                            0 degrees to 350 degrees (Compass Direction)

Measurement Accuracy:

   Range: 0 degrees to 347 degrees:........................+/-6(Degrees)
   Range: < 0 degrees or > 347 degrees:...................+/-8 (Degrees)
   Range: 0 degrees to 340 degrees:........................+/-10 degrees
                                                     (Compass Direction)
   Range: <0 degrees or > 340 degrees:.....................+/-20 degrees
                                                     (Compass Direction)

Resolution:..................................................1 (Degrees)
                                          10 degrees (Compass Direction)

Sampling Cycle Frequency (Degrees and Compass Direction):......5 seconds


WIND CHILL TEMPERATURE

Operating Measurement:.....................-121 degrees to 140 degrees F
                                          (- 85 degrees to 60 degrees C)

Accuracy: Range: 2 to 56 m/s:............................+/-16 degrees F
                                                       (+/-18 degrees C)

Resolution:....................................2 degrees F (1 degrees C)

Sampling Cycle Frequency:......................................5 seconds


RAINFALL

Daily and Cumulative Operating Measurement:...0 to 394 in (0 to 9999 mm)

Rainfall Rate Operating Measurement:...0 to 39.32 in/hr (0 to 998 mm/hr)

Daily Rainfall Accuracy:
   Range: <.6 in (15 mm):.....................+/-.04 in (1 mm) +/-1 unit
   Range: .6 to 394 in (15 to 9999 mm):..................+/-5% +/-1 unit

Cumulative Rainfall Accuracy:
   Range: <.8 in (20 mm):.....................+/-.04 in (1 mm) +/-1 unit
   Range: .8 to 394 in (20 to 9999 mm):.................../-5% +/-1 unit

Rainfall Rate Accuracy:
   Range: < .6 in/hr (15 mm/hr):.................+/-4 in/hr (+/-1 mm/hr)
   Range: .6 to 39.32 in/hr (15 to 998 mm/hr):...............+/-4% or-7%

Daily and Cumulative Resolution:..........................04 inch (1 mm)

Rainfall Rate Resolution:.............................04 in/hr (1 mm/hr)

Daily and Cumulative Sampling Cycle Frequency:..................24 hours

Rainfall Rate Sampling Cycle Frequency:.........Varies Based on Rainfall
                                                Frequency


GENERAL

Display:............................................Liquid Crystal (LCD)

Clock Accuracy:.......................................+/-0.5 Seconds/Day

Power Requirement:................................................12V DC

Battery Life (Alkaline):..................................About 36 Hours

Display Unit Dimensions (HWD):..........4 1/4 x 6 5 /16 x 1 11/16 Inches
                                                     (108 x 176 x 43 mm)

Weight:

  Display Unit (without batteries):......................10.6 oz (300 g)

  8-Way Modular Connection Cord:...........................3.0 oz (85 g)

  Connection Box:..........................................1.4 oz (40 g)

  Rain Gauge (with modular cord and screen):..............9.7 oz (274 g)

  Anemometer (with modular cord, u-bolts, and nuts):.....15.5 oz (440 g)

Thermo-Hygro Sensor (with modular cord):..................5.5 oz (155 g)

Specifications are typical; individual units might vary.  Specifications
are subject to change and improvement without notice.